One short circuit protection by relay


Figure 1 : One short circuit protection by relay


The operation starts by pressing the switch SW2, the circuit will supply power, the green LED will turn on and if an overload occurs The protection circuit will cut off the power immediately, the red LED will turn on






1.RELAY 12V
2.R1-R2  1K 1/4W
3.LED1 Red ,LED2 Green
4.SW2  Micro Switch 




Dimmer Motor with IC555



Equipment list

IC1 - NE555
R1 - 1K
R2 - 47 ohm
C1 - 0.1uF
C2 - 0.01uF
C3 - 470uF/25V
D1,D2 - 1N4148
D3      - 1N4007
VR1 - 50K
Q1 - IRF540